Ultrasonic Bulk Water Meters – ARAD Octave

New call-to-action

  • Replace XXX with size (050, 080, 100, 150, 200)
  • Code example: AD-OCT-080 (i.e. 80mm, 3 inch, Table D flange)
  • Table D flange (BSP avail in 2 inch size only)
  • Dual Beam Ultrasonic
  • No moving parts
  • Long life battery – up to 15 years
  • No installation restrictions
  • 16 bar, 50 deg C max
  • Optional 4-20mA output (loop powered), or open collector pulse output
  • Watermark for 40mm and 50mm threaded Octave meters only
Compare
SKU: AD-OCT-XXX Category: Brand:

Description

Superseded
ARAD OCTAVE DN50-200 Pattern Approval
ARAD Octave Data Sheet Rel 4.02 2019
ARAD-OCTAVE-Installation-Manual_EN_140819
Superseded
ARAD OCTAVE DN50-200 Pattern Approval
ARAD Octave Data Sheet Rel 4.02 2019
ARAD-OCTAVE-Installation-Manual_EN_140819
Name
Superseded

Additional information

Variables Measured

Flow Volume

Outputs

4-20mA, Pulse

Max Flow / Pressure (Head)

100 m3/hr @ 16 bar, 250 m3/hr @ 16 bar, 40 m3/hr @ 16 bar, 400 m3/hr @ 16 bar, 63 m3/hr @ 16 bar

Max Pressure / Temp

16 bar @ 50°C

Port Size

100mm Table D Flange, 150mm Table D Flange, 2 inch BSP Male, 200mm Table D Flange, 50mm Table D Flange, 80mm Table D Flange

Materials

Polyester Coated Cast Iron Body

IP Rating

IP65